Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters

Database
Language
Document Type
Year range
1.
Biomedicines ; 10(12)2022 Dec 01.
Article in English | MEDLINE | ID: covidwho-2142493

ABSTRACT

Introduction: SARS-CoV-2 serology have several indications. Currently, as there are various types available, it is important to master their performance in order to choose the best test for the indication. We evaluated and compared four different commercial serology tests, three of them had the Food and Drug Administration Emergency Use Authorization (FDA-EUA). Our goal was to provide new data to help guide the interpretation and the choice of the serological tests. Methods: Four commercial tests were studied: Elecsys® Roche® on Cobas® (total anti-nucleocapsid (N) antibodies), VIDAS® Biomerieux® (IgM and IgG anti- receptor binding domain (RBD) antibodies), Mindray® (IgM and IgG anti-N and anti-RBD antibodies) and Access® Beckman Coulter® (IgG anti-RBD antibodies). Two panels were tested: a positive panel (n = 72 sera) obtained from COVID-19-confirmed patients with no vaccination history and a negative panel (n = 119) of pre-pandemic sera. The analytical performances were evaluated and the ROC curve was drawn to assess the manufacturer's cut-off for each test. Results: A large range of variability between the tests was found. The Mindray®IgG and Cobas® tests showed the best overall sensitivity, which was equal to 79.2% CI 95% (67.9−87.8). The Cobas® test showed the best sensitivity after 14 days of COVID-19 molecular confirmation; which was equal to 85.4% CI 95% (72.2−93.9). The Access® test had a lower sensitivity, even after day 14 (55.5% CI 95% (43.4−67.3)). The best specificity was noted for the Cobas®, VIDAS®IgG and Access® IgG tests (100% CI 95% (96.9−100)). The IgM tests, VIDAS®IgM and Mindray®IgM, showed the lowest specificity and sensitivity rates. Overall, only 43 out of 72 sera (59.7%) showed concordant results by all tests. Retained cut-offs for a significantly better sensitivity and accuracy, without significant change in the specificity, were: 0.87 for Vidas®IgM (p = 0.01) and 0.14 for Access® (p < 10−4). The combination of Cobas® with Vidas® IgM and IgG offered the best accuracy in comparison with all other tests combinations. Conclusion: Although using an FDA-EUA approved serology test, each laboratory should carry out its own evaluation. Tests variability may raise some concerns that seroprevalence studies may vary significantly based on the used serology test.

2.
J Clin Virol ; 152: 105169, 2022 07.
Article in English | MEDLINE | ID: covidwho-1804471

ABSTRACT

The virus neutralization test (VNT) is the reference for the assessment of the functional ability of neutralizing antibodies (NAb) to block SARS-CoV-2 entry into cells. New competitive immunoassays measuring antibodies preventing interaction between the spike protein and its cellular receptor are proposed as surrogate VNT (sVNT). We tested three commercial sVNT (a qualitative immunochromatographic test and two quantitative immunoassays named YHLO and TECO) together with a conventional anti-spike IgG assay (bioMérieux) in comparison with an in-house plaque reduction neutralization test (PRNT50) using the original 19A strain and different variants of concern (VOC), on a panel of 306 sera from naturally-infected or vaccinated patients. The qualitative test was rapidly discarded because of poor sensitivity and specificity. Areas under the curve of YHLO and TECO assays were, respectively, 85.83 and 84.07 (p-value >0.05) using a positivity threshold of 20 for PRNT50, and 95.63 and 90.35 (p-value =0.02) using a threshold of 80. However, the performances of YHLO and bioMérieux were very close for both thresholds, demonstrating the absence of added value of sVNT compared to a conventional assay for the evaluation of the presence of NAb in seropositive subjects. In addition, the PRNT50 assay showed a reduction of NAb titers towards different VOC in comparison to the 19A strain that could not be appreciated by the commercial tests. Despite the good correlation between the anti-spike antibody titer and the titer of NAb by PRNT50, our results highlight the difficulty to distinguish true NAb among the anti-RBD antibodies with commercial user-friendly immunoassays.


Subject(s)
COVID-19 , SARS-CoV-2 , Antibodies, Neutralizing , Antibodies, Viral , COVID-19/diagnosis , Humans , Neutralization Tests/methods
SELECTION OF CITATIONS
SEARCH DETAIL